Features:
• Online Double-Conversion.
• DSP Technology Guarantees High Reliability. • True Inbuilt Galvanic Isolation Transformer Design. Control Designed to Withstand all kinds of Loads.
Intelligent Battery Management to Prolong Battery Life Cycle. Redundant Fan Design and Independent Ventilation Enhances Durable Operation Under Harsh Environment.
Adjustable Battery Numbers.
• Accept Dual-Mains Input.
• Parallel Operation with up to 6 Units (Option). Variety of Communication Options Available.
⚫ 7" Inch Colour Touch Screen Display
• IGBT based charger for smart battery management & improve input power factor
• EPO & ECO Mode Operation
MODELEPX+3310L32
CAPACITY10KVA
INPUT
Rated AC Voltage
380V / 400V / 415V AC (3Ph+N+PE)
Voltage Range
290V - 480V, AC ± 5V
Frequency Range
50/60 Hz ± 10%
Auto Sensing
Power Factor
≥0.99
Walk-in Time
5 - 300 Sec
(Configurable)
BYPASS
Rated Voltage
380V / 400V / 415V AC (3Ph+N+PE)
Voltage Range
.+ 20% -30% (Configurable)
Frequency Range
50 / 60 Hz * 10% (Configurable)
BATTERY
Battery Voltage
384V DC Standard (360 - 408 Configurable)
Ripple
≥1%
Charging Current Max. (A)
0.10C to 0.25C upto 100-300Ah at 100% Load
(Configurable)
OUTPUT
Rated Voltage
380V/400V/415VAC(3Ph+N)
Frequency Range
Auto Sensing 50/60 Hz
± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode
Voltage Regulation
± 1%
Harmonic Distortion (THDV)
≤ 1% Linear Load, ≤ 5% Non-Linear Load
Crest Factor / Transfer Time
3:1/ Zero
Efficiency
Up to 95% Dual Conversion Mode, 99% ECO Mode
Overload
≤110% for 60 Min, ≤125% for 10 Min ≤ 150% for 1 Min,
> 150% for 300 ms
SYSTEM FEATURES
Parallel
Up to 6 Units (Optional)
Display
Touch Screen & LED Mimic Diagram
IP Rating
IP 20
Alarm / Protection
Short Circuit, Input Under/Over Voltage,Over
Temperature Over Current,
Audible Alarms
Alarm for batt. Low, DC High, Inverter Under/Over
Voltage, Overload Short Circuit, Fan Failure & UPS Fault
LED Indicatios
Bypass, Mains, Battery and Fault
LCD Display Information
Input Voltage
& Freq; Output Voltage, Current KVA KW , Total Power PF , Load %
Per Phase
Load % Total & Frequency ; Bypass Voltage &
Freq; Inverter Voltage & Freq ; Battery Voltage ,
DC Bus Voltage, Charging Curtrent , Discharging
Current , Temperature
ENVIRONMENTAL
Temperature
Operating: 0-45°C , Storage: -10°C - 55°C
Humidity / Altitude
0~95% RH Non-condersing / <1500 M
Noise
Low Audible Noise Level
STANDARDS
Quality
ISO 9001, ISO 14001, ISO 27001, ISO45001 ISO 50001,
RoHS
Safety
IEC/EN62040-1
EMC / Performance
IEC/EN62040-2; IEC/EN62040-3,Complying to CE
PHYSICAL
Dimensions WxDxH (mm)
350x650x1050
Weight (Kg)
148
COMMUNICATION INTERFACE
Standard
RS-232
Optional
SNMP /ModBus/Dry Contact / USB / RS-485
Monitoring Software
NetAgent /Muser4000
Specifications are subject to changes without prior
notice *
20KVA MODEL EPX+3320L32
CAPACITY 20KVA
INPUT
Rated AC Voltage 380V / 400V / 415V AC (3Ph+N+PE)
Voltage Range 290V - 480V, AC ± 5V
Frequency Range 50/60 Hz ± 10%
Auto Sensing Power Factor ≥0.99
Walk-in Time 5 - 300 Sec (Configurable)
BYPASS
Rated Voltage 380V / 400V / 415V AC (3Ph+N+PE)
Voltage Range .+ 20% -30% (Configurable)
Frequency Range 50 / 60 Hz * 10% (Configurable)
BATTERY
Battery Voltage 384V DC Standard (360 - 408 Configurable)
Ripple ≥1%
Charging Current Max. (A) 0.10C to 0.25C upto 100-300Ah at 100% Load
(Configurable)
OUTPUT
Rated Voltage 380V/400V/415VAC(3Ph+N)
Frequency Range Auto Sensing 50/60 Hz ± 1~10% Sync Mode (Configurable),
50/60 Hz ± 0.1 Hz Battery Mode
Voltage Regulation ± 1%
Harmonic Distortion (THDV) ≤ 1% Linear Load, ≤ 5% Non-Linear Load
Crest Factor / Transfer Time 3:1/ Zero
Efficiency Up to 95% Dual Conversion Mode, 99% ECO Mode
Overload ≤110% for 60 Min, ≤125% for 10 Min ≤ 150% for 1 Min, > 150% for 300
ms
SYSTEM FEATURES
Parallel Up to 6 Units (Optional)
Display Touch Screen & LED Mimic Diagram
IP Rating IP 20
Alarm / Protection Short Circuit, Input Under/Over Voltage,Over Temperature
Over Current,
Audible Alarms Alarm for batt. Low, DC High, Inverter Under/Over Voltage,
Overload Short Circuit, Fan Failure & UPS Fault
LED Indicatios Bypass, Mains, Battery and Fault
LCD Display Information Input Voltage & Freq; Output Voltage, Current
KVA KW , Total Power PF , Load % Per Phase Load % Total & Frequency ;
Bypass Voltage & Freq; Inverter Voltage & Freq ; Battery Voltage , DC
Bus Voltage, Charging Curtrent , Discharging Current , Temperature
ENVIRONMENTAL
Temperature Operating: 0-45°C , Storage: -10°C - 55°C
Humidity / Altitude 0~95% RH Non-condersing / <1500 M
Noise Low Audible Noise Level
STANDARDS
Quality ISO 9001, ISO 14001, ISO 27001, ISO45001 ISO 50001, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3,Complying to CE
PHYSICAL
Dimensions WxDxH (mm) 350x650x1050
Weight (Kg) 168
COMMUNICATION INTERFACE
Standard RS-232
Optional SNMP /ModBus/Dry Contact / USB / RS-485
Monitoring Software NetAgent /Muser4000
Specifications are subject to changes without prior notice *
30KVA MODEL EPX+3330L32
CAPACITY 30KVA
INPUT
Rated AC Voltage 380V / 400V / 415V AC (3Ph+N+PE)
Voltage Range 290V - 480V, AC ± 5V
Frequency Range 50/60 Hz ± 10%
Auto Sensing Power Factor ≥0.99
Walk-in Time 5 - 300 Sec (Configurable)
BYPASS
Rated Voltage 380V / 400V / 415V AC (3Ph+N+PE)
Voltage Range .+ 20% -30% (Configurable)
Frequency Range 50 / 60 Hz * 10% (Configurable)
BATTERY
Battery Voltage 384V DC Standard (360 - 408 Configurable)
Ripple ≥1%
Charging Current Max. (A) 0.10C to 0.25C upto 100-300Ah at 100% Load
(Configurable)
OUTPUT
Rated Voltage 380V/400V/415VAC(3Ph+N)
Frequency Range Auto Sensing 50/60 Hz ± 1~10% Sync Mode (Configurable),
50/60 Hz ± 0.1 Hz Battery Mode
Voltage Regulation ± 1%
Harmonic Distortion (THDV) ≤ 1% Linear Load, ≤ 5% Non-Linear Load
Crest Factor / Transfer Time 3:1/ Zero
Efficiency Up to 95% Dual Conversion Mode, 99% ECO Mode
Overload ≤110% for 60 Min, ≤125% for 10 Min ≤ 150% for 1 Min, > 150% for 300
ms
SYSTEM FEATURES
Parallel Up to 6 Units (Optional)
Display Touch Screen & LED Mimic Diagram
IP Rating IP 20
Alarm / Protection Short Circuit, Input Under/Over Voltage,Over Temperature
Over Current,
Audible Alarms Alarm for batt. Low, DC High, Inverter Under/Over Voltage,
Overload Short Circuit, Fan Failure & UPS Fault
LED Indicatios Bypass, Mains, Battery and Fault
LCD Display Information Input Voltage & Freq; Output Voltage, Current
KVA KW , Total Power PF , Load % Per Phase Load % Total & Frequency ;
Bypass Voltage & Freq; Inverter Voltage & Freq ; Battery Voltage , DC
Bus Voltage, Charging Curtrent , Discharging Current , Temperature
ENVIRONMENTAL
Temperature Operating: 0-45°C , Storage: -10°C - 55°C
Humidity / Altitude 0~95% RH Non-condersing / <1500 M
Noise Low Audible Noise Level
STANDARDS
Quality ISO 9001, ISO 14001, ISO 27001, ISO45001 ISO 50001, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3,Complying to CE
PHYSICAL
Dimensions WxDxH (mm) 430x830x1100
Weight (Kg) 230
COMMUNICATION INTERFACE
Standard RS-232
Optional SNMP /ModBus/Dry Contact / USB / RS-485
Monitoring Software NetAgent /Muser4000
Specifications are subject to changes without prior notice *
40KVA MODEL EPX+3340L32
CAPACITY 40KVA
INPUT
Rated AC Voltage 380V / 400V / 415V AC (3Ph+N+PE)
Voltage Range 290V - 480V, AC ± 5V
Frequency Range 50/60 Hz ± 10%
Auto Sensing Power Factor ≥0.99
Walk-in Time 5 - 300 Sec (Configurable)
BYPASS
Rated Voltage 380V / 400V / 415V AC (3Ph+N+PE)
Voltage Range .+ 20% -30% (Configurable)
Frequency Range 50 / 60 Hz * 10% (Configurable)
BATTERY
Battery Voltage 384V DC Standard (360 - 408 Configurable)
Ripple ≥1%
Charging Current Max. (A) 0.10C to 0.25C upto 100-300Ah at 100% Load
(Configurable)
OUTPUT
Rated Voltage 380V/400V/415VAC(3Ph+N)
Frequency Range Auto Sensing 50/60 Hz ± 1~10% Sync Mode (Configurable),
50/60 Hz ± 0.1 Hz Battery Mode
Voltage Regulation ± 1%
Harmonic Distortion (THDV) ≤ 1% Linear Load, ≤ 5% Non-Linear Load
Crest Factor / Transfer Time 3:1/ Zero
Efficiency Up to 95% Dual Conversion Mode, 99% ECO Mode
Overload ≤110% for 60 Min, ≤125% for 10 Min ≤ 150% for 1 Min, > 150% for 300
ms
SYSTEM FEATURES
Parallel Up to 6 Units (Optional)
Display Touch Screen & LED Mimic Diagram
IP Rating IP 20
Alarm / Protection Short Circuit, Input Under/Over Voltage,Over Temperature
Over Current,
Audible Alarms Alarm for batt. Low, DC High, Inverter Under/Over Voltage,
Overload Short Circuit, Fan Failure & UPS Fault
LED Indicatios Bypass, Mains, Battery and Fault
LCD Display Information Input Voltage & Freq; Output Voltage, Current
KVA KW , Total Power PF , Load % Per Phase Load % Total & Frequency ;
Bypass Voltage & Freq; Inverter Voltage & Freq ; Battery Voltage , DC
Bus Voltage, Charging Curtrent , Discharging Current , Temperature
ENVIRONMENTAL
Temperature Operating: 0-45°C , Storage: -10°C - 55°C
Humidity / Altitude 0~95% RH Non-condersing / <1500 M
Noise Low Audible Noise Level
STANDARDS
Quality ISO 9001, ISO 14001, ISO 27001, ISO45001 ISO 50001, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3,Complying to CE
PHYSICAL
Dimensions WxDxH (mm) 430x830x1100
Weight (Kg) 255
COMMUNICATION INTERFACE
Standard RS-232
Optional SNMP /ModBus/Dry Contact / USB / RS-485
Monitoring Software NetAgent /Muser4000
Specifications are subject to changes without prior notice *